Newton's law of cooling
The hotter something is compared with its surroundings, the faster it loses heat, so it cools quickly at first and then ever more slowly. The gap to room temperature halves in equal steps of time, however hot it started.
The physics
- Newton's law of cooling: the temperature changes at a rate proportional to the gap to the surroundings, dT/dt = −k (T − Ta), with Ta the surroundings' temperature and k the cooling constant.
- The curve: T(t) = Ta + (T0 − Ta) e−k t, with T0 the starting temperature. The same formula covers warming: a cold drink rises toward a warm room.
- Half-life: the gap halves every ln 2 ÷ k. The time to reach a temperature T is t = ln((T0 − Ta) ÷ (T − Ta)) ÷ k.
- Finding k: measure the temperature twice, T1 at time t1 and T2 at t2: k = ln((T1 − Ta) ÷ (T2 − Ta)) ÷ (t2 − t1).
Assumptions and limits: k depends on the object, its container, a lid, stirring and moving air, so no value is given for any particular drink or material; find yours from two readings. The law assumes the object is at one temperature throughout and loses heat in proportion to the gap, which holds best for small gaps and moving air; radiation and evaporation (an open cup of hot water) make real cooling faster at high temperatures than this curve. The surroundings stay at one temperature. Tested: the formula is checked against a step-by-step (Runge–Kutta) integration of the differential equation, the half-life and time-to-temperature against the curve, and k recovered from two readings (packages/mechanics/test/science.test.ts).
Example
With starting temperature 90°C, surroundings 20°C, cooling constant k 0.04 per minute, target temperature 60°C: temperature after 10 minutes: 66.9 °C; time to reach the target temperature: 14 min; half-life (the gap to the surroundings halves): 17.3 min; cooling rate: -2.8 °C per minute at the start. Open this setup, then change one thing at a time.
Related: RC circuit · Tank drain time · Spring–mass–damper