Venturi meter (Bernoulli)

Speed in the pipe
Speed in the throat
Pressure drop
Manometer difference

The same water has to get through the narrow throat each second, so it speeds up. The extra speed comes from pressure, which is why the tube over the throat stands lower. Measure that difference and you know the flow.

The physics

Ideal flow (no friction); real meters are calibrated with a discharge coefficient a little below 1. The throat can't be wider than the pipe (the page caps it 5 mm smaller), and the drawn columns are capped to fit while the readout gives the real difference. Tested: energy per litre is the same in pipe and throat, and the inverse formula gives back the flow (packages/mechanics/test/fluids.test.ts).

Example

With flow (litres per second) = 2, pipe diameter 50 mm, throat diameter 25 mm: speed in the pipe: 1.02 m/s; speed in the throat: 4.07 m/s; pressure drop: 7.78 kPa; manometer difference: 793.2 mm of water. Open this setup, then change one thing at a time.

Related: Siphon · Tank drain time · Water pressure at depth