Check valve (non-return valve)

Cracking pressure
Valve now
Pressure for full lift (6 mm)

A spring holds a poppet against a seat. Pressure from the left pushes it open; pressure from the right only presses it harder onto the seat, so flow can only go one way.

The physics

This is the static balance only: in a real valve the moving flow also pushes on the poppet and the seal touches over a slightly different area, so a measured cracking pressure is close to this but not exact. Tested: the cracking pressure against a hand calculation, and the lift limits (packages/mechanics/test/fluids.test.ts).

Example

With spring rate 2 N/mm, spring preload 4 mm, seat diameter 10 mm, peak upstream pressure 2 bar: cracking pressure: 1.02 bar (14.8 psi); valve now: shut; pressure for full lift (6 mm): 2.55 bar (36.9 psi). Open this setup, then change one thing at a time.

Related: Pressure relief valve · Float valve (ballcock) · Coil spring rate calculator